(0)

AMI 300 Series

The AMI 300 Series can accurately produce surface area and pore size results of powder materials. According to the different test functions, this series of instruments are divided into three types, there are A, B, and C. Every analysis station has its own dedicated dosing manifold for optimal analysis duration. The C type is configured with 1 torr or 0.1 torr high-sensitive pressure sensors and turbo molecular pump with ultimate pressure of 10-8 Pa. The three analysis stations can also be used for in-situ sample preparation to avoid sample contamination. It can effectively take microporous analysis of microporous materials such as molecular sieve, catalyst, activated carbon, and other microporous materials.

  • Single-/Multipoint BET Surface Area
  • BJH Adsorption and Desorption
  • Horvath-Kawazoe
  • Saito-Foley
  • Material Research
  • Chemical Engineering
  • New Energy
  • Catalytic Technologies

Description

Specifications

Type Meso 300A Micro 300B Micro 300C
Adsorbed Gas Non corrosive gases, such as N2, Ar, Kr, H2, O2, CO2, CO, NH3, CH4, etc.
Pressure Sensor at Analysis Station 1000 torr, 3 1000 torr, 3;

10 torr, 1 (optional 2 or 3);

1 torr (0.1torr can be selected), 1 (optional 2 or 3)

1000 torr, 3;

10 torr, 3;

1 torr (0.1torr can be selected), 3

Accuracy: ±0.15% (F.S.)
Pressure Sensor at P0 Station 1000 torr, 3

(Accuracy: ±0.15% (F.S.)

Degas System

 

The standard configuration is 3 stations in-situ degassing, which can simultaneously degas 3 samples under vacuum heating;

Another option is external 4-station vacuum heating degassing machine

Degas Temperature Ambient to 400 oC. Free to set up target temperature.
Vacuum Pump

 

Two-stage rotary vane mechanical vacuum pump,

the ultimate pressure is

6.7*10-2 Pa

Two-stage rotary vane mechanical vacuum pump, the ultimate  pressure is 6.7*10-2 Pa,  optional turbo molecular pump Turbo molecular pump (ultimate pressure 10-8Pa) and front mechanical vacuum pump (ultimate pressure 6.7*10-2 Pa)

 

Analysis Port Samples on the 3 analysis bits can be tested at same time (including P0 test).
Test Principle Gas adsorption by static-volumetric analysis
Measurement Range of

BET Surface Area

0.0005 m2/g to the infinity;

Standard sample repeatable accuracy is less than ± 1.0%

0.0001m2/g to the infinity;

Standard sample repeatable accuracy is less than ± 1.0%

0.0001m2/g to the infinity;

Standard sample repeatable accuracy is less than ± 1.0%

 

Test Range of Pore Diameter

 

0.35 nm-500 nm;

Pore dimension repeatability is less than 0.2 nm in the accurately analyses porous materials with pore size greater than 2 nm

0.35 nm-500 nm;

Pore dimension repeatability is less than 0.02 nm in the accurate analysis of micropore 0.35 nm-2 nm

0.35 nm-500 nm;

Pore dimension repeatability is less than 0.02 nm in the

accurate analysis of micropore 0.35 nm-2 nm

 

Minimum Pore Volume 0.0001 cm3/g
Range of Relative Pressure P/P0 10-5-0.998

 

10-6/10-8-0.998

 

10-8-0.998

 

Overall Dimension Depth: 700 mm; width: 700 mm; height: 850 mm; weight: 80 Kg -90 Kg
Ambient Temperature 15-40 oC

 

Related Humidity 30%-60%
Electrical Supply AC220 V ± 20 V, 50/60 HZ, maximum power 300W;

Applications

Applied Field Typical Materials Details
Material Research ceramic powder, metal powder, nanotube According to surface area value of nanotube, hydrogen storage capacity can be predicted.
Chemical Engineering carbon black, amorphous silica, zinc oxide, titanium dioxide Surface area of carbon black is one of the important factors affecting the reinforcement performance of rubber products.
New Energy lithium cobalt, lithium manganate Increasing surface area of electrode can improve Electrochemical reaction rate and promote iron exchange in negative electrode.
Catalytic Technologies active alumina oxide, molecular sieve, zeolite Active surface area and pore structure influence reaction rate.

 